- Verify cooling performance, temperature drop, and determine if adjustments are necessary.
- Clean outdoor condenser coil and remove debris from unit.
- Inspect condenser fan motor operation, and lubricate as necessary.
- Check amperage of compressor for proper operation.
- Test operation and condition of compressor contactor.
- Inspect and tighten electrical connections.
- Inspect and test start/run capacitors and relays.
- Visually inspect for refrigerant leaks.
- Inspect indoor evaporator coil, if accessible.
- Flush and clear condensate drain to protect against overflow.
- Inspect blower assembly operation and cleanliness, lubricate and adjust as necessary.
- Evaluate condition of air filters and other indoor air quality accessories.
- Test and adjust all safeties and controls for proper operation.
- Calibrate thermostat and confirm proper operation.
- Evaluate overall efficiency of system and inform customer of equipment condition and needed repairs.
|
|
- Cleaning heat exchanger and inspect for combustion leaks or cracks.
- Testing for Carbon Monoxide during inspection, verifying the parts per million inside the home during heater operation.
- Clean burners and adjust for maximum efficiency.
- Clean pilot assembly and inspect thermocouple and/or flame sensor integrity.
- Inspect flame sensor integrity.
- Examine flue pipe connections and inspect venting system.
- Verify proper inducer motor operation and integrity.
- Verify proper ignition control and sequence of operation.
- Inspect gas piping and valve for leaks and operation.
- Flush condensate drain to protect against overflow.
- Inspect blower assembly cleanliness and proper heating speed, lubricate and adjust as necessary.
- Evaluate condition of air filters and other indoor air quality accessories.
- Test and adjust all safeties for proper operation and over-limiting shutdown.
- Calibrate thermostat and confirm proper operation.
- Evaluate the overall efficiency of the system and inform customer of equipment condition and needed repairs if any.
|
|
- Inspect and test heater elements in emergency heat mode.
- Inspect and test reversing valve operation.
- Inspect and test defrost control system and auxiliary heat operation.
|
**Some of these procedures are not applicable to certain areas mainly in the southern United States. In these instances, cooling demands are generally greater resulting in the need for semi-annual cooling tune-ups rather than heating tune ups due the need for more cooling months than heating, these options are available upon request.
|